Description: |
On explosive productions any electric equipment without special protection can be an ignition source with following explosion. It is necessary to observe safety regulations to avoid loss of human lifes and huge financial losses. Observance of rules guarantees risk decrease on dangerous productions. One of leading suppliers for explosion-proof load-lifting devices are producers from Bulgaria which are famous for the approach to quality of production. Production is supervised by ISO 9001:2000 system. All hoists have necessary documents, including the certificate for the European Union and Russia.
Electric hoists have following features:
– Explosion-proof covering for all basic elements, where the emergence spark can occure (marked by letter d).
– Actuators are protected from an overheat.
– Possibility execution «under hydrogen». Similar models are marked by Exd IICT5.
– Bench test for all hoists.
– Hoist can be done according to specification of the customer.
Technical characteristics: |
Loading capacity (kg) | from 500 |
Height of lifting (m) | 6,0 – 75,0 |
Operating mode: | FEM 9,511 -1Аm-4mISO 4301/1 – М3-М7 GOST (Russian) 25835 – 1М-5М |
Speed of lifting (m/min) | 4,0; 6,0; 8,0; 12,0; 16,0; 24,0; 32,0; |
Micro speed of lifting (m/min) | 0.7/4.0; 0.7/6.0; 1.4/8.0; 1.4/12.0; 2.0/16.0; 2.8/24.0; 4.0/32.0; |
Speed of movement (m/min) | 8.0; 10.0; 12.0; 15.0; 20.0; 32.0; 12.0/4.0; 15.0/5.0 20.0/6.0; 32.0/10.0; |
Climatic modification | from 25С till +40С from 43С till +40С from 25С till +50С |
Voltage | 380V / 50Hz |
Updatings: |
– standard polyspast 2/1;
– standard polyspast 4/1;
– with small construction height, polyspast 2/1;
– with small construction height, polyspast 4/1;
– stationary on pins, polyspast 2/1;
– stationary polyspast 2/1;
Additional features: |
– radio control;
– micro speed on lifting/movement;
– additional brake on the lifting mechanism;
Description: |
Electric hoists are standardly made with following options: class of the explosive zone V-I; category of explosive mixes (ExdIIB T4).
Marking example 1ExdIAT3 | 1 | Ex | d | IA | T3 |
Explosion-proof sign | Compliance to standards | Explosion-proof option | Subgroup sign (category of the mix) | Temperature class (category of the mix) |
1ExdIAT3 – the creation of flame extinguishing zone is put in the explosion-proof basis. Flame passing through this zone is cooling down. Hoists with explosion-proof execution have: the lifting electric motor with rotor and the built-in brake; the movement electric motor with the built-in disk brake, an electrocase with contactors; the transformer; the relay wit thermal protection; trailer switches; the main contactor and a push-button pult of management. (Ex) – the electric equipment which design prevents possibility of ignition inside the explosive environment. d– explosion-proof execution of electric equipment. All volumes were the electric spark or ignition can occure are executed with safety regulations. Their cover doesn’t collapse under high pressure of gases. The flame from explosion passes through the increased flange gap between details of the case and is cooled down to safe temperature.